Circuit breaker, PowerPacT J, 250A, 3 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, ABC molded case
Manufacturer: Schneider Electric
Device short name: PowerPact H
Poles description: 3P
Breaking capacity code:D
[Uimp] rated impulse withstand voltage: 8 kV IEC 60947-2
Line Rated Current: 250 A
The PowerPacT J-Frame circuit breakers are engineered to safeguard electrical systems against the detrimental effects of overloads and short circuits, particularly in applications involving motors with variable speed and variable frequency motors. They come with a choice of thermal-magnetic or MicroLogic electronic trip protection units, making them ideal for protecting electrical starters and various pressure transducer types. Specifically, this variant of the PowerPacT J-Frame offers thermal-magnetic protection with an impressive interrupting capacity of 14kA at 600VAC.
In the variable frequency drive market, where efficiency and reliability are paramount, the PowerPacT J-Frame breakers stand out. Equipped with dual-break rotating contacts, all PowerPacT J-Frame breakers minimize peak current during short circuit faults, ensuring the smooth operation of inductive switches and variable frequency drive pumps. They also provide protection against thermal overload, a common issue in vfd drives for pumps.
The 250A, 3-pole PowerPacT J circuit breaker boasts a breaking capacity of 14kA at 600VAC and has a continuous current rating of 80% with an ABC phase connection. These breakers are housed in stainless steel electrical enclosures, adding an extra layer of durability and protection.
Compliant with UL, CSA, NOM, and IEC standards, and CE marked, these breakers are a must-have for any electrical warehouse. For all electrics, from circuit breaker descriptions to the latest in variable frequency drive technology, the PowerPacT J-Frame offers unparalleled protection and performance.
Main
| Product name | PowerPact H |
| Device short name | JDA175 |
| Product or component type | Circuit breaker |
| Device application | Distribution |
| Poles description | 3P |
| Protected poles description | D |
| [In] rated current | 250 A |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz IEC 60947-3 |
| [Icu] rated ultimate short-circuit breaking capacity | 100 kA 220/240 V AC 50/60 Hz IEC 60947-2
65 kA 380/440/415 V AC 50/60 Hz IEC 60947-2
25 kA 500/525 V AC 50/60 Hz IEC 60947-2
20 kA 250 V DC IEC 60947-2
20 kA 500 V DC IEC 60947-2
|
| Performance level | 14 kA |
| Trip unit technology | Thermal-magnetic |