Circuit breaker ComPacT NSX100F, 36kA at 415VAC, TMD trip unit 100A, 3 poles 3d
Manufacturer: Schneider Electric
Device short name: NSX100H
Poles description: 3P
Protected poles description: 3D
[In] rated current: 100 A at 40 °C
Performance level: F 36kA 415V AC
Trip unit name: TM-D
The ComPacT NSX100F is a comprehensive 3-pole, 3-phase fixed circuit breaker engineered to maximize space efficiency and enhance breaking capacity. It serves as an ideal solution for both standard and specialized applications, offering unparalleled performance and reliability.
With a breaking capacity (Icu) of 36kA rms at 415VAC, 50/60Hz, the ComPacT NSX100F is capable of handling high-current faults effortlessly. The operational voltage of this breaker is 690VAC, 50/60Hz, ensuring compatibility with a wide range of electrical systems.
The product features a 100A-rated thermal-magnetic trip unit (TMD), which provides adjustable thermal overload protection and fixed magnetic short-circuit protection. This ensures that the breaker can respond appropriately to various fault conditions, protecting equipment and personnel from potential harm.
The 3-pole version of the ComPacT NSX100F, measuring 105mm x 161mm x 86mm, comes with a variety of optional functions and accessories to suit specific needs. Whether you require additional safety features, monitoring capabilities, or connectivity options, the ComPacT NSX100F has you covered.
Compliance with international standards is paramount, and the ComPacT NSX100F meets the requirements of IEC 60947, CCC, EAC, and marine specifications. Additionally, this breaker is part of Schneider Electric's EcoStruxure Power architecture, ensuring seamless integration with modern power management systems and contributing to a more sustainable and efficient energy future.
Main
| Product name | ComPacT NSX new generation |
| Device short name | NSX100H |
| Product or component type | Circuit breaker |
| Device application | Distribution |
| Poles description | 3P |
| Protected poles description | 3D |
| [In] rated current | 100 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| [Icu] rated ultimate short-circuit breaking capacity | 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
|
| Performance level | F 36 kA 415 V AC |
| Trip unit name | TM-D |