Circuit breaker, ComPacT NS1000L, 150kA at 415VAC, 4P, fixed, manually operated, MicroLogic 5.0 control unit, 1000A
Manufacturer: Schneider Electric
Device short name: NS1000L
Poles description: 4P
Protected poles description: 4D
(In) rated current up to 65 °C: 1000 A at 50 °C
Performance level: L 150 kA 415 V AC
Trip unit name: MicroLogic 5.0
The ComPacT NS1000L distribution circuit breaker is an advanced and reliable component specifically designed for electrical distribution systems. At its core lies the MicroLogic 5.0 trigger, which boasts a rated current of 1000A, providing precise and rapid protection against electrical faults.
This circuit breaker features a 4P4D configuration and PdC L type, delivering exceptional performance with a rated short-circuit capacity of 150kA and a rated voltage of 415Vca. This ensures stable and reliable operation within a frequency range of 50/60Hz, making it suitable for a wide range of electrical systems.
The design of the ComPacT NS1000L takes into account the convenience of installation. Its fixed mounting design allows for seamless integration into existing systems. The manual operation and front-mounted terminals further enhance its user-friendliness. Additionally, its compact design, with a width of only 280mm, enables easy installation even in tight spaces.
In terms of safety, this circuit breaker meets IP40 ingress protection and IK07 impact resistance ratings, ensuring its durability and safety in various environmental conditions. Its compliance with the CEI 60947-2 standard further demonstrates its superior performance and long-term stability.
Overall, the ComPacT NS1000L distribution circuit breaker with MicroLogic 5.0 trigger is an ideal choice for electrical distribution systems. Its exceptional performance, compact design, and outstanding safety features provide reliable protection for various electrical applications.
Main
| Product name | ComPacT NS new generation |
| Device short name | NS1000L |
| Product or component type | Circuit breaker |
| Device application | Distribution |
| Poles description | 4P |
| Protected poles description | 4D |
| (In) rated current up to 65 °C | 1000 A at 50 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| [Icu] rated ultimate short-circuit breaking capacity | 150 kA Icu at 220/240 V AC 50/60 Hz IEC 60947-2
150 kA Icu at 380/415 V AC 50/60 Hz IEC 60947-2
130 kA Icu at 440 V AC 50/60 Hz IEC 60947-2
100 kA Icu at 500/525 V AC 50/60 Hz IEC 60947-2
|
| Performance level | L 150 kA 415 V AC |
| Trip unit name | MicroLogic 5.0 |